Q: I have a remote customer and they have an AudioCodes Mediant 1000 gateway with some FXO modules installed. I wanted to determine if their modules were FXO or FXO G modules. How can I determine this?
A: The standard FXO module supports outdoor and indoor (lightning protection) loop-start signaling. The FXO G module supports both loop- and ground start signaling (but only supports indoor protection).